Flow range

Technical Parameter
Project | Parameter |
Speed range | ≤100rpm |
External control speed control resolution | 0.1rpm |
*Direction control | External input empty contact, contact disconnected, peristaltic pump operates clockwise; The contact is closed and the peristaltic pump operates counterclockwise. |
*Start stop control | External input empty contact, contact disconnected, peristaltic pump running; The contact closes and the peristaltic pump stops. |
*Dial switch speed control | 16 speed BCD dial switch, 0 speed corresponding to external signal control, 1-F speed corresponding to rpm 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100 |
*External signal speed control (optional) | 4-20mA linear corresponds to 0.1-100rpm, 0-5V linear corresponds to 0-100rpm, 0-10V linear corresponds to 0-100rpm, 0-10kHz linear corresponds to 0-100rpm, |
**Communication address setting | 5-bit DIP dial switch, communication address setting range from 1 to 30, 31 for broadcast address |
**Communication Baud Rate Setting | 1-bit DIP dial switch, available at 1200bps or 9600bps |
Overall dimensions (L×W×H) | 183×102×136(mm) |
Relative humidity of working environment | <80% |
Ambient Temperature | 0°C~40°C |
Applicable power supply | DC11.4V-25.2V/20W |
Weight | 1.43kg |
Explanation: The project is unique to the combination of dial switch and external signal control method** The project is unique to the RS 485 communication control method.
Product Selection Table
Model | Control mode |
TS100 series | DIP switch combined with external signal(4-20mA) |
DIP switch combined with external signal(0-5mA) |
DIP switch combined with external signal(0-10mA) |
DIP switch combined with external signal(0-10kHz) |
RS485 communication |